C. K. Wong
- A New Methodology for Calibrating the Lowry Model. In: Journal of Urban Planning and Development, v. 124, n. 2 (June 1998). (1998):
- Probabilistic characteristics of damping in buildings. In: Wind & Structures, v. 2, n. 2 (June 1999). (1999):
- Using neural networks to model and predict amplitude dependent damping in buildings. In: Wind & Structures, v. 2, n. 1 (March 1999). (1999):
- On-line Health Monitoring and Damage Detection of Structures Based on the Wavelet Transform. In: International Journal of Structural Stability and Dynamics, v. 8, n. 3 (September 2008). (2008):
- The effect of amplitude-dependent damping on wind-induced vibrations of a super tall building. In: Journal of Wind Engineering and Industrial Aerodynamics, v. 91, n. 9 (September 2003). (2003):
- Random damping in buildings and its AR model. In: Journal of Wind Engineering and Industrial Aerodynamics, v. 79, n. 1-2 (January 1999). (1999):
- Full scale measurements of wind effects on tall buildings. In: Journal of Wind Engineering and Industrial Aerodynamics, v. 74-76 (April 1998). (1998):
- Optimization of Vertical Elevator Movements and Material Storage Locations for High-Rise Building Construction with Overtime Cost Effects. In: Journal of Computing in Civil Engineering, v. 33, n. 1 (January 2019). (2019):
- Evaluation of carbonation resistance of paint coated concrete for buildings. In: Construction and Building Materials, v. 107 (March 2016). (2016):
-
Evaluation of wind effects on a supertall building based on full-scale measurements. In: Earthquake Engineering and Structural Dynamics, v. 29, n. 12 (December 2000).
https://doi.org/10.1002/1096-9845(200012)29:12<1845::aid-eqe995>3.0.co;2-q
(2000): - Optimization of tower crane and material supply locations in a high-rise building site by mixed-integer linear programming. In: Automation in Construction, v. 20, n. 5 (August 2011). (2011):
- Optimization of material hoisting operations and storage locations in multi-storey building construction by mixed-integer programming. In: Automation in Construction, v. 19, n. 5 (August 2010). (2010):
- Full Scale Measurements of Damping in a 78-storey Tall Building. In: Advances in Structural Engineering, v. 2, n. 1 (December 1998). (1998):
- Symmetry Reduction of Structures for Large Rotations. In: Advances in Structural Engineering, v. 3, n. 1 (January 2000). (2000):
- Wind effects on a very tall building and wavelet analysis. In: Proceedings of the Institution of Civil Engineers - Structures and Buildings, v. 140, n. 2 (May 2000). (2000):
- Serviceability of a 79-storey tall building under typhoon conditions. In: Proceedings of the Institution of Civil Engineers - Structures and Buildings, v. 158, n. 4 (August 2005). (2005):
- Optimisation of site layout planning for multiple construction stages with safety considerations and requirements. In: Automation in Construction, v. 53 (May 2015). (2015):
- Comparison of Using Mixed-Integer Programming and Genetic Algorithms for Construction Site Facility Layout Planning. In: Journal of Construction Engineering and Management, v. 136, n. 10 (October 2010). (2010):
- Damping in buildings: its neural network model and AR model. In: Engineering Structures, v. 22, n. 9 (September 2000). (2000):
- Field measurements of typhoon effects on a super tall building. In: Engineering Structures, v. 26, n. 2 (January 2004). (2004):
- Full-scale measurements and numerical evaluation of wind-induced vibration of a 63-story reinforced concrete tall building. In: Engineering Structures, v. 26, n. 12 (October 2004). (2004):
- Effect of temperature and galvanization on the compressive strength of cold-formed angles. In: Canadian Journal of Civil Engineering / Revue canadienne de génie civil, v. 17, n. 3 (June 1990). (1990):
- Discretized Cell Modeling for Optimal Facility Layout Plans of Unequal and Irregular Facilities. In: Journal of Construction Engineering and Management, v. 143, n. 1 (January 2017). (2017):
- Optimization of crane setup location and servicing schedule for urgent material requests with non-homogeneous and non-fixed material supply. In: Automation in Construction, v. 89 (May 2018). (2018):
- Field measurements of amplitude-dependent damping in a 79-storey tall building and its efects on the structural dynamic responses. In: The Structural Design of Tall Buildings, v. 11, n. 2 ( 2002). (2002):
- Field measurements of wind effects on the tallest building in Hong Kong. In: The Structural Design of Tall and Special Buildings, v. 12, n. 1 ( 2003). (2003):
-
Field measurements of wind and structural responses of a 70-storey tall building under typhoon conditions. In: The Structural Design of Tall Buildings, v. 9, n. 5 ( 2000).
https://doi.org/10.1002/1099-1794(200012)9:5<325::aid-tal169>3.0.co;2-b
(2000):