0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

General Information

Completion: 1997
Status: in use

Project Type

Location

Location: , ,

Technical Information

Dimensions

total length 25.00 m
main spans (2x) 12.5 m
total width 1.93 m
walkway width 1.500 m
truss height 1.48 m

Design Loads

snow load 1.2 kN/m²

Materials

truss fiber-reinforced polymer (FRP)
abutments reinforced concrete
pier reinforced concrete

Chronology

1998

Bridge is taken into a laboratory for testing of the bolted and glued joints.

Notes

The bridge consist of a glued and a bolted span in order to test the difference between the two types of construction. The spans are removed every spring and put back in place by helicopter in the fall. This is to avoid them being swept away by flooding in the months where the Flaz carries more water. The effects of the harsh environment are tested regularly both in terms of overall structural stiffness as well as masterial strength.

Participants

Design
Composite construction

Relevant Web Sites

Relevant Publications

  • About this
    data sheet
  • Structure-ID
    20005206
  • Published on:
    20/09/2002
  • Last updated on:
    22/09/2022
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine