Synergistic Impact on Indoor Air Quality: The Combined Use of Air Conditioners, Air Purifiers, and Fresh Air Systems

Author(s):







Medium: journal article
Language(s): English
Published in: Buildings, , n. 6, v. 14
Page(s): 1562
DOI: 10.3390/buildings14061562
Abstract:

As concerns about indoor air quality increase, air purifiers and fresh air systems are increasingly being used in conjunction with air conditioners in office buildings. To study the synergistic effects of multisystem joint operation on indoor air quality, this study used a combination of experimental and simulation methods to study the indoor particulate matter with a diameter of less than 2.5 µm (PM2.5) and carbon dioxide (CO2) concentrations under different operation conditions. The purification time and the PM2.5 concentration distribution under different conditions were compared with the condition in which the purifier was used alone. The results showed that the purification time required for the condition that the air conditioner runs together with the purifier was shortened by 15.2%. When the fresh air system is running together with the purifier, the purification time can be reduced by 30.4%. It was reduced by 32.6% when the three systems were operating at the same time. The PM2.5 concentration distribution under the joint operating condition was much more even than that under the condition in which the purifier was running alone. To analyze the impact on the CO2 distribution, the CO2 distributions under different joint operations were compared. The results show that the fresh air system can effectively dilute CO2 below 1000 ppm in 30 min. The air conditioner and purifier could help to mix the indoor air to provide a much more uniform indoor CO2 distribution.

Copyright: © 2024 by the authors; licensee MDPI, Basel, Switzerland.
License:

This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met.

  • About this
    data sheet
  • Reference-ID
    10787495
  • Published on:
    20/06/2024
  • Last updated on:
    20/06/2024
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine