Membranwirkung von Verbunddecken bei Brand - Experimentelle Untersuchungen
Author(s): |
Martin Mensinger
Peter Schaumann Martin Stadler Jörg Sothmann |
---|---|
Medium: | journal article |
Language(s): | German |
Published in: | Stahlbau, August 2011, n. 8, v. 80 |
Page(s): | 561-565 |
DOI: | 10.1002/stab.201101455 |
Abstract: |
Membrane Action of Composite Slabs in Fire - Experimental Investigation.Composite beam slab systems show a very good behaviour in case of fire. Due to large deformations membrane forces are activated inside the slab and wider spans can be bridged. Secondary beams are not necessary at elevated temperatures and can be left unprotected. In Great Britain and Switzerland membrane action is already used to design slab systems in fire ([1] to [5]). To enable such design rules in Germany further investigations are required. For this reason a research project was initiated by the authors. The project is supported by the DASt and AiF. In [6] the state of research and the idea of membrane action are already described. In this paper the experimental part of the project is presented. |
Keywords: |
fire test membrane force span composite construction span length fire design slab
|