Mauerwerksbauten des Wohnungsbaus unter Erdbebeneinwirkung
Festlegung konstruktiver Maßnahmen für den Entfall eines genaueren Nachweises in den Erdbebenzonen 2 und 3
Author(s): |
Wolfram Jäger
Song Ha Nguyen Peter Schöps |
---|---|
Medium: | journal article |
Language(s): | German |
Published in: | Mauerwerk, April 2010, n. 2, v. 14 |
Page(s): | 96-105 |
DOI: | 10.1002/dama.201000460 |
Abstract: |
Masonry structures in housebuilding under earthquake actions.Definition of structural provisions for abdication of calculational verification in the earthquake zones 2 and 3. Results of a research project funded by the Federal Office for Building and Regional Planning will be presented. It affiliates to a previous one on masonry structures in earthquake zone 1 [1]. The necessary crosssection areas according to DIN 4149 were recalculated for standard masonry structures for housebuilding. The there contained table has the advantage, that a calculational verification should not be done if the cross sectional area of the stiffening walls comply with the given minimum values. These values could be approved in generally and accordingly reduced in most cases, if the adequate material data were used for the respectively unitmortar-combination. |
Keywords: |
DIN 4149 earthquake verification cross sectional area for shear walls minimum values of shear wall cross sectional area earthquake zone
|
Available from: | Refer to publisher |
- About this
data sheet - Reference-ID
10058637 - Published on:
17/11/2010 - Last updated on:
30/09/2018