0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Fire Risk Assessment and Experimental Study of Transformer Insulating Oil

Author(s):


ORCID


Medium: journal article
Language(s): English
Published in: Advances in Civil Engineering, , v. 2022
Page(s): 1-12
DOI: 10.1155/2022/7185045
Abstract:

Most previous works concentrated on burning characteristics of pool fire using common fuels such as heptane, propane, biodiesel, and diesel, whereas burning characteristics for transformer oil are barely involved, although transformer oil is arguable of more practical importance in power system. This study performed a series of pool fire experiments using transformer oil to study the burning characteristics in open and confined spaces. Three fuel thicknesses and five initial temperatures are changed in open space. The essential parameters of mass loss rate, flame height, and fire plume temperature are obtained and analyzed. Moreover, three oil pool diameters are varied in a chamber. The main conclusions are summarized as follows: the variations of mass loss rate, flame height, and fire plume temperature not only obviously increase as the fuel thickness increases from 0.5 cm to 1.0 cm, but also insignificantly increase as the fuel thickness changes from 1.0 cm to 2.0 cm. The mass loss rate is less sensitive to the initial temperature of transformer oil, but the flame height and fire plume temperature significantly rise with the initial temperature. Moreover, the modified models to predict the flame height and fire plume temperature for 25°C initial temperature conditions are proposed, but the fitting coefficients are obviously different from that for common liquid fuels. The flame height in confined space is higher and will rapidly increase to the maximum, then decreases, and tends to be stable, which is obviously different from the oil pool fire burning in open space. In addition, the phenomenon of burning blast and the ignition of the adjacent oil pool will be observed with a high-temperature ignition source and a certain high temperature in a chamber under 30 cm oil pool diameter, which will not be recorded in 15 cm and 20 cm.

Copyright: © Ji Jun et al. et al.
License:

This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met.

  • About this
    data sheet
  • Reference-ID
    10679026
  • Published on:
    18/06/2022
  • Last updated on:
    10/11/2022
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine