Evaluation of the compressive strength of autoclaved aerated concrete in existing masonry

Author(s): ORCID

ORCID
Medium: journal article
Language(s): English
Published in: ce/papers, , n. 2, v. 6
Page(s): 142-149
DOI: 10.1002/cepa.1964
Abstract:

Sclerometric method, commonly used in reinforced concrete structures, have also found application in masonry structures, mainly in the diagnosis of brick masonry walls or testing mortar in joints. This article presents a proposal for determining the compressive strength of autoclaved aerated concrete masonry elements with the use of the Schmidt OS‐120 PT pendulum hammer. The test was carried out on masonry elements with a nominal density class of 400 and 600. Additional tests were also carried out on samples with different levels of humidity, in order to consider the influence of humidity on the change in rebound number and changes in compressive strength.

Structurae cannot make the full text of this publication available at this time. The full text can be accessed through the publisher via the DOI: 10.1002/cepa.1964.