0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Dynamic strength analysis of the key components of the beam-type pumping unit with dynamic tracking balance

Author(s):
Medium: journal article
Language(s): English
Published in: Frattura ed Integrità Strutturale, , n. 57, v. 15
Page(s): 291-299
DOI: 10.3221/igf-esis.57.21
Abstract:

Aiming at the shortages of large reversing impact, high energy consumption and poor balance effect of conventional beam-type pumping unit, the design scheme of beam-type pumping unit with dynamic tracking balance is proposed. The load-displacement curves from on-site trial shows that pumping with dynamic tracking balance has a better balance effect, and a production and power efficiency. According to the designed structure, the dynamic responses of the beam and connecting rods are analyzed. The results show that the maximum Mises stresses in the beam and connecting rod are 36.96 MPa and 27.83 MPa, respectively. The key components of designed beam-type pumping unit with dynamic tracking balance meet the requirement of strength.

Structurae cannot make the full text of this publication available at this time. The full text can be accessed through the publisher via the DOI: 10.3221/igf-esis.57.21.
  • About this
    data sheet
  • Reference-ID
    10614282
  • Published on:
    08/07/2021
  • Last updated on:
    08/07/2021
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine