0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Pile Foundation Seismic Design Approach for the Padma Bridge, Bangladesh

Author(s): (Associate Director, AECOM Asia Co., Ltd., Hong Kong, 20F Grand Central Plaza, Shatin, Hong Kong.)
(Principal Engineer, Benaim, Hong Kong)
(Associate Director, AECOM Asia Co., Ltd., Hong Kong, 20F Grand Central Plaza, Shatin, Hong Kong)
Medium: conference paper
Language(s): English
Conference: Second International Conference on Geotechnical and Earthquake Engineering, Chengdu, China, October 25-27, 2013
DOI: 10.1061/9780784413128.072
Abstract: Padma River is 6 km wide at the location of the proposed bridge. The estimated riverbed scour is 62 m deep with a return period of 100 years. Due to the proximity of Bangladesh to the tectonic plate contact zones of the Himalayas, the site is prone to seismic events. The deep scour and seismicity made the foundation design very challenging. A detailed, state-of-the-art ground investigation was carried out down to a depth of about 160 m in the predominant micaceous sands encountered to establish the static and dynamic soil parameters. Undisturbed samples of sand were recovered using the GEL PUSH sampling technique. State-of-the-art insitu tests, the self-boring insitu friction tests (SBIFTs), cross-hole seismic shear wave and compression wave tomography, self-boring pressuremeter tests, and flat plate dilatometer tests were carried out. Cyclic triaxial loading tests, bender element tests, k0-consolidated stress path compression and extension tests were carried out. A structural numerical model developed using MIDAS software comprising six 150-m-long spans was developed including the piles at each pier. Using the dynamic design soil parameters, the ground response was determined using SHAKE, with strong ground motions corresponding to a 475-year return period earthquake event. They were then input into the MIDAS dynamic soil-structure interaction model with the Penzien Method to design the piles and the superstructure, taking due note of the deep design scour depths. The analyses demonstrate that six 3-m diameter steel raking piles driven down to about 120 m are needed to support each bridge pier with the 150-m span truss girders placed on seismic isolation bearings.

Structures and Projects

Structurae cannot make the full text of this publication available at this time. The full text can be accessed through the publisher via the DOI: 10.1061/9780784413128.072.
  • About this
    data sheet
  • Reference-ID
    10703483
  • Published on:
    27/01/2023
  • Last updated on:
    27/01/2023
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine