One-sided repair of corroded steel girder end with high-strength bolted doubler plate and evaluation of its resiliency after the repair

 One-sided repair of corroded steel girder end with high-strength bolted doubler plate and evaluation of its resiliency after the repair
Author(s): , ,
Presented at IABSE Congress: Resilient technologies for sustainable infrastructure, Christchurch, New Zealand, 3-5 February 2021, published in , pp. 597-604
DOI: 10.2749/christchurch.2021.0597
Price: € 25.00 incl. VAT for PDF document  
ADD TO CART
Download preview file (PDF) 0.23 MB

Repair of steel girder end is sometimes conducted from one side when work space is restricted or corrosion extent is small. This study focuses on repair with high-strength bolted doubler plate as e...
Read more

Bibliographic Details

Author(s): (Kumamoto University, Kumamoto, JAPAN)
(Osaka City University, Osaka, JAPAN)
(Osaka City University, Osaka, JAPAN)
Medium: conference paper
Language(s): English
Conference: IABSE Congress: Resilient technologies for sustainable infrastructure, Christchurch, New Zealand, 3-5 February 2021
Published in:
Page(s): 597-604 Total no. of pages: 8
Page(s): 597-604
Total no. of pages: 8
DOI: 10.2749/christchurch.2021.0597
Abstract:

Repair of steel girder end is sometimes conducted from one side when work space is restricted or corrosion extent is small. This study focuses on repair with high-strength bolted doubler plate as effective and quick one-sided repair method of corroded girder end. FEA was conducted to evaluate the resistance of intact, corroded and repaired girder and to investigate geometrical dimensions of the doubler plate for enhancing its resiliency. From obtained results, both high repair effect and resiliency can be secured with one-sided bolted and small plate, if the web plate and bearing stiffener is prevented from buckling. As contact force between doubler plate and lower flange is the most important to resisting mechanism, they should be touched with each other. Regarding bolt arrangement, it’d be desirable to reduce the distance between lower flange and end bolt. Finally, the repair work such as jack-up and perforation has almost no influence on the ultimate strength.

Keywords:
corrosion bolted connection resiliency Doubler Plate Repairs