0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Investigations and testing of full-scale glass roofs for individual approval

 Investigations and testing of full-scale glass roofs for individual approval
Author(s): , ,
Presented at IABSE Symposium: Sustainable Infrastructure - Environment Friendly, Safe and Resource Efficient, Bangkok, Thailand, 9-11 September 2009, published in , pp. 148-157
DOI: 10.2749/222137809796088800
Price: € 25.00 incl. VAT for PDF document  
ADD TO CART
Download preview file (PDF) 0.19 MB

The TU Dresden is decisively involved in the development of a sustainable and transparent glazed roof structure. The designed transparent space grid structure is based on a conventional steel space...
Read more

Bibliographic Details

Author(s):


Medium: conference paper
Language(s): English
Conference: IABSE Symposium: Sustainable Infrastructure - Environment Friendly, Safe and Resource Efficient, Bangkok, Thailand, 9-11 September 2009
Published in:
Page(s): 148-157 Total no. of pages: 8
Page(s): 148-157
Total no. of pages: 8
Year: 2009
DOI: 10.2749/222137809796088800
Abstract:

The TU Dresden is decisively involved in the development of a sustainable and transparent glazed roof structure. The designed transparent space grid structure is based on a conventional steel space grid, in which all steel members of the compression layer are replaced by glass panes. The glazing transfers large in-plane forces and serves as roof covering.

Two full-scale mock-ups of a double layer space grid structure in the structure geometries half- octahedron plus tetrahedron and half-Vierendeel demonstrated the feasibility to build such new structures.

To achieve an individual approval comprehensive testing was conducted. This included small sized testing of block elements for the local load application into the glass edge, in-plane stability tests, walk-on and post breakage behaviour tests and load bearing tests at roof strips of about 15 m length. In the structural tests the glazing had to resist a load with the safety factor of 3.0.

Keywords:
testing roof glass experiments space structure mock-up long span module grid individual approval