0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Influence of Anchor Length and Drilled Hole on Mechanical Behaviour of Masonry Column Structures Strengthened with Bonded Anchor

 Influence of Anchor Length and Drilled Hole on Mechanical Behaviour of Masonry Column Structures Strengthened with Bonded Anchor
Author(s): , , ,
Presented at IABSE Symposium: Challenges for Existing and Oncoming Structures, Prague, Czech Republic, 25-27 May 2022, published in , pp. 1204-1211
DOI: 10.2749/prague.2022.1204
Price: € 25.00 incl. VAT for PDF document  
ADD TO CART
Download preview file (PDF) 0.13 MB

Masonry structures like stone lanterns are collapsed by lateral forces and cracked by deterioration. Some of them should be repaired without changing their original appearance as heritage structure...
Read more

Bibliographic Details

Author(s): (Kumamoto University, Kumamoto, JAPAN)
(Kumamoto University, Kumamoto, JAPAN)
(Kumamoto University, Kumamoto, JAPAN)
(Kumamoto University, Kumamoto, JAPAN)
Medium: conference paper
Language(s): English
Conference: IABSE Symposium: Challenges for Existing and Oncoming Structures, Prague, Czech Republic, 25-27 May 2022
Published in:
Page(s): 1204-1211 Total no. of pages: 8
Page(s): 1204-1211
Total no. of pages: 8
DOI: 10.2749/prague.2022.1204
Abstract:

Masonry structures like stone lanterns are collapsed by lateral forces and cracked by deterioration. Some of them should be repaired without changing their original appearance as heritage structures. One way to solve the problems is bonded anchoring, but the design criteria are not established in Japan. Therefore, this paper conducted pull-out tests to investigate the mechanical behaviour of strengthened parts with a bonded anchor. The maximum load and stiffness in load versus pull-out displacement were proportional to embedment length in any failure modes, whereas they did not vary by drilled-hole diameter. Three modes; cone failure, combined failure of cone and pull-out failure, and split failure were confirmed. Since the split failure occurred regardless of embedment length and drilled hole diameter, it seems to be related to initial cracks or compositions and uneven distribution of composed minerals and particles in the strengthened stone.

Keywords:
pull-out tests bonded anchor Masonry Column Structures Ultimate Resistance
Copyright: © 2022 International Association for Bridge and Structural Engineering (IABSE)
License:

This creative work is copyrighted material and may not be used without explicit approval by the author and/or copyright owner.