0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Influence of Anchor Length and Drilled Hole on Mechanical Behaviour of Masonry Column Structures Strengthened with Bonded Anchor

 Influence of Anchor Length and Drilled Hole on Mechanical Behaviour of Masonry Column Structures Strengthened with Bonded Anchor
Autor(en): , , ,
Beitrag für IABSE Symposium: Challenges for Existing and Oncoming Structures, Prague, Czech Republic, 25-27 May 2022, veröffentlicht in , S. 1204-1211
DOI: 10.2749/prague.2022.1204
Preis: € 25,00 inkl. MwSt. als PDF-Dokument  
ZUM EINKAUFSWAGEN HINZUFÜGEN
Vorschau herunterladen (PDF-Datei) 0.13 MB

Masonry structures like stone lanterns are collapsed by lateral forces and cracked by deterioration. Some of them should be repaired without changing their original appearance as heritage structure...
Weiterlesen

Bibliografische Angaben

Autor(en): (Kumamoto University, Kumamoto, JAPAN)
(Kumamoto University, Kumamoto, JAPAN)
(Kumamoto University, Kumamoto, JAPAN)
(Kumamoto University, Kumamoto, JAPAN)
Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Symposium: Challenges for Existing and Oncoming Structures, Prague, Czech Republic, 25-27 May 2022
Veröffentlicht in:
Seite(n): 1204-1211 Anzahl der Seiten (im PDF): 8
Seite(n): 1204-1211
Anzahl der Seiten (im PDF): 8
DOI: 10.2749/prague.2022.1204
Abstrakt:

Masonry structures like stone lanterns are collapsed by lateral forces and cracked by deterioration. Some of them should be repaired without changing their original appearance as heritage structures. One way to solve the problems is bonded anchoring, but the design criteria are not established in Japan. Therefore, this paper conducted pull-out tests to investigate the mechanical behaviour of strengthened parts with a bonded anchor. The maximum load and stiffness in load versus pull-out displacement were proportional to embedment length in any failure modes, whereas they did not vary by drilled-hole diameter. Three modes; cone failure, combined failure of cone and pull-out failure, and split failure were confirmed. Since the split failure occurred regardless of embedment length and drilled hole diameter, it seems to be related to initial cracks or compositions and uneven distribution of composed minerals and particles in the strengthened stone.

Stichwörter:
Pull-Out-Versuche
Copyright: © 2022 International Association for Bridge and Structural Engineering (IABSE)
Lizenz:

Die Urheberrechte (Copyright) für dieses Werk sind rechtlich geschützt. Es darf nicht ohne die Zustimmung des Autors/der Autorin oder Rechteinhabers/-in weiter benutzt werden.