Experimental Investigation of the Punching Shear Behaviour of RC Slab-Column Connections Under Seismic Loading

 Experimental Investigation of the Punching Shear Behaviour of RC Slab-Column Connections Under Seismic Loading
Author(s): , , ,
Presented at IABSE Conference: Engineering the Developing World, Kuala Lumpur, Malaysia, 25-27 April 2018, published in , pp. 403-410
DOI: 10.2749/kualalumpur.2018.0403
Price: € 25.00 incl. VAT for PDF document  
ADD TO CART
Download preview file (PDF) 0.27 MB

Reinforced concrete flat slab-column structures are widely used because of their practicality. However, this type of structures can be subjected to punching-shear failure with in the slab-column co...
Read more

Bibliographic Details

Author(s): (Assistant Lecturer, Structural Engineering Department, Badr University, Cairo, EGYPT)
(Associate Professor, RC Institute, Housing and Building National Research Center, Giza, EGYPT)
(Professor, Structural Engineering Department, Ain Shams University, Cairo, EGYPT)
(Professor, Civil Engineering Department, Mataria, Helwan University, Cairo, EGYPT)
Medium: conference paper
Language(s): English
Conference: IABSE Conference: Engineering the Developing World, Kuala Lumpur, Malaysia, 25-27 April 2018
Published in:
Page(s): 403-410 Total no. of pages: 8
Page(s): 403-410
Total no. of pages: 8
DOI: 10.2749/kualalumpur.2018.0403
Abstract:

Reinforced concrete flat slab-column structures are widely used because of their practicality. However, this type of structures can be subjected to punching-shear failure with in the slab-column connections. Without shear reinforcement, the slab-column connection can undergo brittle punching failure, especially when the structure is subjected to lateral loading in seismic zones. This research is a part of an extensive investigation about the punching shear behavior of interior RC slab-column connections under seismic loading. The current paper represents only the results of the first two tested specimens. The main objective is to discuss the nature and mechanism of effect seismic loading on punching shear behaviour. Finally, the experimental results are analyzed and compared to international codes such as American Code ACI318-14[1] and Euro Code EC2-2004[2]. In light of these results, some preliminary conclusions are presented.

papers will be distributed in the electronic conference proceedings.

Keywords:
seismic loading punching shear shear studs Interior slab-column connections