0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Experimental and Numerical Study on the Seismic Performance of Precast Bridge Column with an Improved Grouted Corrugated Duct Connection Design

 Experimental and Numerical Study on the Seismic Performance of Precast Bridge Column with an Improved Grouted Corrugated Duct Connection Design
Author(s): , , ,
Presented at IABSE Congress: Bridges and Structures: Connection, Integration and Harmonisation, Nanjing, People's Republic of China, 21-23 September 2022, published in , pp. 1919-1926
DOI: 10.2749/nanjing.2022.1919
Price: € 25.00 incl. VAT for PDF document  
ADD TO CART
Download preview file (PDF) 0.18 MB

In this paper, an improved connection design of the precast bridge column is proposed, including new design of grouted corrugated steel duct and a shallow recess pocket at the top of footing connec...
Read more

Bibliographic Details

Author(s): (Tongji University, Shanghai, China)
(Tongji University, Shanghai, China)
(Tongji University, Shanghai, China)
(Shanghai Typhoon Institute, Shanghai, China)
Medium: conference paper
Language(s): English
Conference: IABSE Congress: Bridges and Structures: Connection, Integration and Harmonisation, Nanjing, People's Republic of China, 21-23 September 2022
Published in:
Page(s): 1919-1926 Total no. of pages: 8
Page(s): 1919-1926
Total no. of pages: 8
DOI: 10.2749/nanjing.2022.1919
Abstract:

In this paper, an improved connection design of the precast bridge column is proposed, including new design of grouted corrugated steel duct and a shallow recess pocket at the top of footing connection for the assembly of precast concrete bridge columns, which has a good seismic performance, durability and facilitate constructability. The improved grouted corrugated steel duct which can increase the bonding mechanism and facilitate constructability expected to perform better than conventional corrugated galvanized steel ducts used for post-tensioning applications. Finite element analysis is then conducted. It is found that the confining effect (support and friction force) provided by recess sidewall keeps the connection in good integrity. It also prevents early deformation and early development of transverse cracks along the connection interface, which further avoids the damage concentration at connection joint, transfers the plastic hinge region.

Keywords:
seismic performance finite element analysis FEA prefabricated concrete bridge column grouted corrugated duct connections quasi-static cyclic test
Copyright: © 2022 International Association for Bridge and Structural Engineering (IABSE)
License:

This creative work is copyrighted material and may not be used without explicit approval by the author and/or copyright owner.