Analysis of the Florida International University Pedestrian Bridge Collapse

 Analysis of the Florida International University Pedestrian Bridge Collapse
Author(s): ,
Presented at IABSE Symposium: Challenges for Existing and Oncoming Structures, Prague, Czech Republic, 25-27 May 2022, published in , pp. 1033-1038
DOI: 10.2749/prague.2022.1033
Price: € 25.00 incl. VAT for PDF document  
ADD TO CART
Download preview file (PDF) 0.23 MB

The paper describes the investigation process of the collapse of the pedestrian bridge in Miami, Florida (USA). The main span concrete truss structure with a length of 174-foot (53 m) collapsed dur...
Read more

Bibliographic Details

Author(s): (FINLEY Engineering Group International, Prague, Czechia)
(FINLEY Engineering Group International, Prague, Czechia)
Medium: conference paper
Language(s): English
Conference: IABSE Symposium: Challenges for Existing and Oncoming Structures, Prague, Czech Republic, 25-27 May 2022
Published in:
Page(s): 1033-1038 Total no. of pages: 6
Page(s): 1033-1038
Total no. of pages: 6
DOI: 10.2749/prague.2022.1033
Abstract:

The paper describes the investigation process of the collapse of the pedestrian bridge in Miami, Florida (USA). The main span concrete truss structure with a length of 174-foot (53 m) collapsed during construction onto the active highway beneath which had fatal consequences. FINLEY was approached to conduct an independent analysis of the bridge structure for one of the subcontractors involved with the project. As part of an analysis of the bridge behavior, detailed calculation models were developed, and advanced method of structural analysis were used. Finite element method (FEM) brick model of the entire span was created and the stresses at the failure area were investigated in detail. Computation FEM models were supplemented and verified by the strut and tie modelling (STM). The construction process and transport of the bridge span was also simulated. The analysis shows the issues and risks associated with the design of structures with a non-transparent flow of internal forces and demonstrates the need for a detailed assessment of joints and critical areas during all phases of the construction process. The results of the analysis were subsequently confirmed by later published investigation report of the US National Transportation Safety Board.

Keywords:
concrete FEM crack pedestrian bridge brick truss collapse node capacity
Copyright: © 2022 International Association for Bridge and Structural Engineering (IABSE)
License:

This creative work is copyrighted material and may not be used without explicit approval by the author and/or copyright owner.