  1. Manz, H. / Huber, H. / Schälin, A. / Weber, A. / Ferrazzini, M. / Studer, M. (2000): Performance of single room ventilation units with recuperative or regenerative heat recovery. In: Energy and Buildings, v. 31, n. 1 (January 2000).

    https://doi.org/10.1016/s0378-7788(98)00077-2

  2. Manz, H. / Huber, H. (2000): Experimental and numerical study of a duct/heat exchanger unit for building ventilation. In: Energy and Buildings, v. 32, n. 2 (July 2000).

    https://doi.org/10.1016/s0378-7788(00)00043-8

  3. Manz, H. / Huber, H. / Helfenfinger, D. (2001): Impact of air leakages and short circuits in ventilation units with heat recovery on ventilation efficiency and energy requirements for heating. In: Energy and Buildings, v. 33, n. 2 (January 2001).

    https://doi.org/10.1016/s0378-7788(00)00077-3

  4. Manz, H. / Frank, Th. (2005): Thermal simulation of buildings with double-skin façades. In: Energy and Buildings, v. 37, n. 11 (November 2005).

    https://doi.org/10.1016/j.enbuild.2005.06.014

  5. Artmann, N. / Jensen, R. L. / Manz, H. / Heiselberg, P. (2010): Experimental investigation of heat transfer during night-time ventilation. In: Energy and Buildings, v. 42, n. 3 (March 2010).

    https://doi.org/10.1016/j.enbuild.2009.10.003

  6. Manz, H. / Loutzenhiser, P. / Frank, T. / Strachan, P. A. / Bundi, R. / Maxwell, G. (2006): Series of experiments for empirical validation of solar gain modeling in building energy simulation codes—Experimental setup, test cell characterization, specifications and uncertainty analysis. In: Building and Environment, v. 41, n. 12 (December 2006).

    https://doi.org/10.1016/j.buildenv.2005.07.020

  7. Favarolo, P. A. / Manz, H. (2005): Temperature-driven single-sided ventilation through a large rectangular opening. In: Building and Environment, v. 40, n. 5 (May 2005).

    https://doi.org/10.1016/j.buildenv.2004.08.003

  8. Manz, H. / Schaelin, A. / Simmler, H. (2004): Airflow patterns and thermal behavior of mechanically ventilated glass double façades. In: Building and Environment, v. 39, n. 9 (September 2004).

    https://doi.org/10.1016/j.buildenv.2004.01.003

  9. Artmann, N. / Gyalistras, D. / Manz, H. / Heiselberg, P. (2008): Impact of climate warming on passive night cooling potential. In: Building Research & Information, v. 36, n. 2 ( 2008).

    https://doi.org/10.1080/09613210701621919

  10. Wullschleger, L. / Manz, H. / Ghazi Wakili, K. (2009): Finite element analysis of temperature-induced deflection of vacuum glazing. In: Construction and Building Materials, v. 23, n. 3 (March 2009).

    https://doi.org/10.1016/j.conbuildmat.2008.07.010

  11. Ghazi Wakili, K. / Tanner, Ch. / Manz, H. (2001): Numerische Analyse zur Anisotropie der Wärmeleitfähigkeit von Ziegel. In: Bauphysik, v. 23, n. 3 (June 2001).

    https://doi.org/10.1002/bapi.200100830