Design of Fire Protection for Steel Girder Bridges
![]() |
|
Détails bibliographiques
Auteur(s): |
Yusuke Imagawa
Osamu Ohyama Akimitsu Kurita |
||||
---|---|---|---|---|---|
Médium: | papier de conférence | ||||
Langue(s): | anglais | ||||
Conférence: | IABSE Symposium: Sustainable Infrastructure - Environment Friendly, Safe and Resource Efficient, Bangkok, Thailand, 9-11 September 2009 | ||||
Publié dans: | IABSE Symposium Bangkok 2009 | ||||
|
|||||
Page(s): | 210-217 | ||||
Nombre total de pages (du PDF): | 6 | ||||
Année: | 2009 | ||||
DOI: | 10.2749/222137809796088198 | ||||
Abstrait: |
From the lessons of many fire accidents of bridge, it concludes that the fire protecting member for bridge, which locates at an intersection of viaduct mainly, is necessary. The authors present the result of the heat transfer analysis for steel girder applied the fire protection material and the structural detail for fire protection in this paper. |