General Information
Project Type
Material: |
Prestressed concrete bridge |
---|---|
Function / usage: |
Road bridge |
Structure: |
Girder bridge |
Construction method: |
In-situ casting on falsework |
Location
Location: |
Boston, Lincolnshire, East Midlands, England, United Kingdom |
---|---|
Address: | Cut End Road |
Coordinates: | 52° 57' 14.06" N 0° 2' 1.14" E |
Technical Information
Dimensions
deck depth | 1.4 m | |
span | 21.9 m | |
total width | 6.1 m | |
roadway / carriageway width | 5.2 m | |
girders | width | 0.380 m |
height | 1.1 m | |
number | 5 |
Materials
deck |
prestressed concrete
|
---|---|
abutments |
reinforced concrete
|
Notes
This is the first cast in-situ prestressed concrete bridge built in England.
Participants
Relevant Web Sites
Relevant Publications
- La reconstruccion del puente de Fishtoft (Inglaterra) con hormigón pretensado in situ. In: Hormigón pretensado, v. 1, n. 2 (1st Quarter 1950), pp. 39-40.
- Reconstruction en béton précontraint sur place du pont de Fishtoft (Angleterre). In: La Technique des Travaux, v. 25, n. 5-6 (May 1949), pp. 157-160.
- About this
data sheet - Structure-ID
20074253 - Published on:
22/11/2017 - Last updated on:
26/11/2017