General Information
Project Type
Function / usage: |
Casino |
---|---|
Material: |
Reinforced concrete structure |
Structure: |
roof: Truss |
Location
Technical Information
Dimensions
width | 20 m | |
length | 50 m | |
number of floors (above ground) | 7 |
Materials
foundations |
reinforced concrete
|
---|---|
truss |
steel
reinforced concrete |
columns |
reinforced concrete
|
walls |
reinforced concrete
|
Notes
First building equipped with stiff shear energy dissipation devices constructed in Lima, Peru. The devices have a double failure mode which makes them extremelly safe and reliable. The devices are made up of mild steel and are very simple to install/remove. The slabs are made up of a spatial truss and two thin layers of concrete with a total self weight of only 4kN/m².
Participants
Structural engineering
- Luis M. Bozzo (structural engineer)
- Miguel Bozzo (structural engineer)
Relevant Web Sites
There currently are no relevant websites listed.
Relevant Publications
- Losas reticulares mixtas. Proyecto, análisis y dimensionamiento. Reverté, Barcelona (Spain), pp. 218. (2003):