Zur konstruktiven Durchbildung des Decke-Stütze-Knotens in Flachdecken aus Elementplatten
Author(s): |
Dominik Kueres
Carsten Siburg Josef Hegger Johannes Furche Thomas Sippel |
---|---|
Medium: | journal article |
Language(s): | German |
Published in: | Bautechnik, June 2016, n. 6, v. 93 |
Page(s): | 356-365 |
DOI: | 10.1002/bate.201500091 |
Abstract: |
Construction of slab-column-connections in semi-precast flat slabsDue to the high degree of prefabrication, semi-precast flat slabs are gaining importance. In this context, the construction of the slab-column-connection has a safety-related significance. In daily engineering practice, the joint widths between semi-precast slabs as well as the joint widths between semi-precast slabs and the column's vicinity is constructed differently. The European Technical Approvals of different punching shear reinforcement systems limit the minimum joint width between semi-precast elements to 4 cm. Following these provisions, the joint widths between semi-precast slabs and the column's vicinity is constructed with 4 cm in some cases. An advantage of this approach is the possibility to adjust dimensional and positional tolerances at construction site. However, a disadvantage is the additional formwork for the joint from the soffit. |
Keywords: |
lattice girder punching flat slab punching shear double-headed anchors lattice girder beam double headed stud semi-precast slab joint width column height tolerances Eurocode 2
|
Available from: | Refer to publisher |