Abstract: |
About the humidity problem in ice rinks.After expertising the structural safety of several ice rinks, it was detected that the constructions of several buildings have to be redeveloped. The long lasting wood moisture of the main structure was predominantly over 20 %. Therefore research into the reason of high wood moisture in ice rinks was made. One fact is the exchange of radiation between the ceiling and the ice. This problem was analysed in tests and suggestions for improvement are made. |
Keywords: |
building physics wooden girder ice area temperature drop structural safety structural stability construction physics radiation emission ratio
|