Windlastempfehlungen für Attikabereiche von Industriehallen auf Basis von Windkanalversuchen
Author(s): |
Frank H. Kemper
Carles Colomer Segura Markus Feldmann Markus Kuhnhenne |
---|---|
Medium: | journal article |
Language(s): | German |
Published in: | Stahlbau, November 2015, n. 11, v. 84 |
Page(s): | 915-921 |
DOI: | 10.1002/stab.201510331 |
Abstract: |
Recommendation of wind load models for parapets on industrial roofs based on wind tunnel measurements.The present contribution shows the results of experimental investigations to determine the wind loading on parapets of industrial buildings with a flat roof. Whereat the presence of parapets is considered in DIN EN 1991-1-4 with respect to their effect on the pressure coefficients at the roof, an appropriate load recommendation for their own design is missing. Based on wind tunnel measurements on scaled models of typical industrial buildings with flat roof, load recommendations have been elaborated to be used in the future design of parapets. |
Keywords: |
load model wind loads boundary layer wind tunnel wind loading DIN EN 1991-1-4 roof area flat roof
|
Available from: | Refer to publisher |
- About this
data sheet - Reference-ID
10072561 - Published on:
30/11/2015 - Last updated on:
30/11/2015