Vereinfachung der Regeln zur Beschränkung der Verformungen nach EC2 - Neuvorschlag für Decken des üblichen Hochbaus
Author(s): |
Frank Prietz
Uwe Richtsteig |
---|---|
Medium: | journal article |
Language(s): | German |
Published in: | Beton- und Stahlbetonbau, April 2015, n. 4, v. 110 |
Page(s): | 275-280 |
DOI: | 10.1002/best.201400119 |
Abstract: |
Simplified rules for deflection control according to EC2 - Proposal for slabs in buildingsEC2 offers two methods for the control of deflections: one without and one with calculating the deflections. Both are not satisfying for the day-to-day work of the practising engineers. In this contribution a proposal for a simplified deflection control is made which provides a direct calculation of the required depth. |
Keywords: |
design Eurocode EC deflection
|
Available from: | Refer to publisher |
- About this
data sheet - Reference-ID
10071664 - Published on:
24/04/2015 - Last updated on:
24/04/2015