Ultrasonic Assessment of the Concrete Residual Strength after a Real Fire Exposure
Author(s): |
Roman Wróblewski
Bohdan Stawiski |
---|---|
Medium: | journal article |
Language(s): | English |
Published in: | Buildings, 19 August 2020, n. 9, v. 10 |
Page(s): | 154 |
DOI: | 10.3390/buildings10090154 |
Abstract: |
After a fire, the assessment of concrete residual strength can be a challenge. Since the strength reduction depends on the distance from the heated surface examination based on destructive test, i.e., core samples, is not precise enough. Therefore, more detailed methods can establish the influence of the high temperature in the zone, which no longer has visible cracks. That method can be used to assess layer thickness to remove due to the fire damage. The Ultrasound Pulse Velocity (UPV) method with point heads was used in the paper to examine samples taken from a structure after the real fire. Moreover, to make the analysis more precise, an effect associated with the porosity in concrete was also considered to separate pure fire effect. |
Copyright: | © 2020 by the authors; licensee MDPI, Basel, Switzerland. |
License: | This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met. |
7.62 MB
- About this
data sheet - Reference-ID
10434738 - Published on:
11/09/2020 - Last updated on:
02/06/2021