Textilbeton verstärkte Platten unter Brandbelastung

Author(s):


Medium: journal article
Language(s): German
Published in: Beton- und Stahlbetonbau, , n. 2, v. 105
Page(s): 102-110
DOI: 10.1002/best.200900069
Abstract:

Textile Reinforced Concrete Strengthened Slabs under Fire Loading

Within an experimental study steel reinforced concrete slabs were produced and strengthened with different types of textile reinforcements. They were than pre-damaged with 125% service load and subsequently exposed to fire loading (ISO-834, Cellulosic curve) under simultaneous service load. The tests lasted up to 60 minutes with no specimen failed. The slabs did not show any visual damage nor concrete spalling. We discuss the presumably reasons for that surprisingly positive test result, although mechanisms are not yet fully understood. The excellent crack control of TRC and load redistribution between textile and steel reinforcement as well as load redistribution in the slabs are assumedly key mechanisms that contribute to the excellent fire resistance.

Keywords:
crack formation fire safety strengthening bending textile-reinforced concrete
Available from: Refer to publisher
Structurae cannot make the full text of this publication available at this time. The full text can be accessed through the publisher via the DOI: 10.1002/best.200900069.