0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Test Method for Appraising Future Durability of New Concrete Bridge Decks

Author(s):




Medium: journal article
Language(s): English
Published in: Transportation Research Record: Journal of the Transportation Research Board, , n. 1, v. 1798
Page(s): 56-63
DOI: 10.3141/1798-09
Abstract:

The nondestructive test procedure for quantifying the future durability of bridge deck concrete is based on the fundamental relationship between ultrasonic pulse velocity (UPV) and the permeability of an elastic medium. An experimental study using standard concrete cylindrical specimens (ASTM C192) documented adequate sensitivity between UPV and permeability. The test procedure uses a parameter directly proportional to increase in-field concrete permeability called paste quality loss (PQL). The PQL is computed from UPV measurements on standard concrete specimens made from field concrete mixture (ASTM C31) and measurements on field concrete. Deck replacement projects on three National Highway System bridges were used as demonstration sites to implement the test procedure. The 56-day PQLs were calculated as 15%, 28%, and 9%, demonstrating a significant variability in the permeability of the three bridge decks. Field permeability tests were also conducted with Figg’s apparatus for comparison purposes. The PQL evaluation from postconstruction measurements is an effective and reliable method for testing the future durability of bridge decks.

Structurae cannot make the full text of this publication available at this time. The full text can be accessed through the publisher via the DOI: 10.3141/1798-09.
  • About this
    data sheet
  • Reference-ID
    10778403
  • Published on:
    12/05/2024
  • Last updated on:
    12/05/2024
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine