Author(s): |
Romana Antczak - Jarząbska
(Politechnika Gdańska Wydział Inżynierii Lądowej i Środowiska)
Maciej Niedostakiewicz (Politechnika Gdańska Wydział Inżynierii Lądowej i Środowiska) |
---|---|
Medium: | journal article |
Language(s): | Polish |
Published in: | Builder, April 2019, n. 4, v. 261 |
Page(s): | 118-122 |
DOI: | 10.5604/01.3001.0013.3567 |
Abstract: |
The paper presents the results of preliminary calculations of the heat transfer coefficient for historic windows made for the state before and after their renovation. The aim of the analysis was to obtain the values of thermal insulation parameters demanded by the regulations, while not losing the historical value of the window. The described example of the thermo-renovation concept of the existing window consisted in installing an additional window panel from the inside. |
- About this
data sheet - Reference-ID
10705063 - Published on:
19/02/2023 - Last updated on:
19/02/2023