0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Study on the Stability of Accumulation Using a Slope Shaking Table Test during Earthquake Action

Author(s):




Medium: journal article
Language(s): English
Published in: Buildings, , n. 1, v. 14
Page(s): 2
DOI: 10.3390/buildings14010002
Abstract:

To examine the effects of different peak accelerations on the stability of the accumulation slope and the effectiveness of anti-slide piles under seismic loads, this paper used the Fanlingqian landslide as the main research object and combined it with digital image correlation (DIC) technology in order to carry out a shaking table test. Then, the acceleration response, displacement field, strain field, the bending moment distribution of the 0.05–0.3 g ground motion accumulation slope, and the anti-slide pile reinforcement were studied. The results of the test show the following: the amplification coefficient of the measuring points A1–A6 of the accumulation slope reaches the maximum at a peak acceleration of 0.2 g, and its values are between 1.25 and 1.3, respectively. Finally, it shows a decreasing trend at a peak acceleration of 0.3 g, and its corresponding values are, respectively, between 1.1 and 1.2. In the anti-slip pile reinforcement test, due to the obstruction of the anti-slip pile, the damping of the soil around the pile increases. As the peak value of the seismic wave input increases, the amplification factor shows an overall decreasing trend. A1–A6 correspond to a peak acceleration of 0.3 g. The amplification factors are all close to 1. During different peak accelerations, the accumulation slope mainly experienced the earthquake-induced stage, tensile failure stage, creeping deformation stage, and overall instability stage. In the anti-slide pile reinforcement test, under the same conditions, the slope mainly experienced the earthquake-induced stage, tensile failure stage, lower sliding surface formation stage, and soil shedding stage in front of the pile. At the same time, the displacement and strain fields of each stage of the two groups of tests are compared, and it is found that the displacement and strain values of the accumulation slope test are greater than those of the anti-slide pile reinforcement test, and the horizontal displacement difference at the top of the slope is the most significant, reaching 2.3 times at the maximum. The bending moment of the anti-slide pile first increases and then decreases with the increase in acceleration, the reverse bending point of the pile appears at 5 times the pile diameter below the soil surface, and the maximum bending moment of the middle pile, corresponding to a peak acceleration of 0.05–0.3 g, is between 7.5 N·m and 47 N·m, respectively, while the maximum bending moment of the outer pile is between 6.5 N·m and 52 N·m, respectively. It is important to apply DIC image processing technology to the monitoring of landslide structure and the evaluation of slope stability in practical engineering.

Copyright: © 2023 by the authors; licensee MDPI, Basel, Switzerland.
License:

This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met.

  • About this
    data sheet
  • Reference-ID
    10753422
  • Published on:
    14/01/2024
  • Last updated on:
    07/02/2024
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine