A Study on the Influence of Hydraulic Compactor Reinforcement on the Force Law of an Independent Foundation Under a Column and Its Safety Standard
Author(s): |
Su Bu
Lishan Chen Hailin Zhang Zhe Qin |
---|---|
Medium: | journal article |
Language(s): | English |
Published in: | Buildings, 22 October 2024, n. 11, v. 14 |
Page(s): | 3331 |
DOI: | 10.3390/buildings14113331 |
Abstract: |
Due to the complexity of the actual geotechnical environment, the backfill compaction design theory and calculation method are not reflected in the current specification. Therefore, in order to investigate the effect of the hydraulic compactor on the foundation structure during the treatment of the backfill of an independent foundation under a column, the Menard formula was modified. At the same time, relying on an independent foundation project under a column in Jinan, the dynamic model of compactor tamping backfilling soil was established. The applicability of the calculation formula is verified by simulating the single-point multiple tamping on the backfill directly above the foundation tie beam, and the influence law of two factors, the thickness of the backfill and the tamping energy, on the force of the foundation tie beam is elucidated. The results show that after reaching the optimum number of tamping, the cumulative soil settlement and the effective reinforcement depth of tamping show a stable trend, and their simulation results are in good agreement with the analytical solution, which provides a supplement to the relevant safety standards. At this critical point, the force on the tie beams peaked and showed up and down fluctuations under the subsequent ramming action. The tamping action of the compactor has a significant effect on the structural forces within the effective reinforcement range, and there is a negative correlation between the magnitude of the structural forces and the thickness of the backfill. According to the numerical calculation results to choose the best construction programme, the on-site monitoring shows that under 42 KJ tamping energy and 1.5 m single backfilling thickness, the tie beam reinforcement stress reaches 18.5~55.5% of the specification warning value, which meets the safety standard. The research results of this paper can provide important guidance for the hydraulic tamping treatment of an independent foundation backfill project. |
- About this
data sheet - Reference-ID
10804405 - Published on:
10/11/2024 - Last updated on:
10/11/2024