Spliced Axially-Loaded Single-Angle Members in Compression
Author(s): |
Sherief S. S. Sakla
Yohanna M. F. Wahba Murty K. S. Madugula |
---|---|
Medium: | journal article |
Language(s): | English |
Published in: | Engineering Journal, March 1999, n. 1, v. 36 |
Page(s): | 4-11 |
DOI: | 10.62913/engj.v36i1.716 |
Abstract: |
Due to construction and transportation considerations, angles used as leg members in latticed towers are often joined together in the field using bolted splice plates. In many instances, the centroid of the angle cross section does not coincide with the centroid of the splice plates used to connect the angles. It is not known what effect such a splice has on the compressive ultimate load carrying capacity of the single-angle member. Reseach results on spliced angle specimens of low slenderness ratio (fabricated according to the communication tower industry practice) and one reference specimen of the same size and length are reported herein and compared with AISC-LRFD Specification. It is shown that the ultimate load carrying capacity of spliced specimen was, on the average, 8 percent less than that of the reference specimen. |