0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Seismic Response of MSE Walls with Various Reinforcement Configurations: Effect of Input Ground Motion Frequency

Author(s): ORCID
ORCID
ORCID
Medium: journal article
Language(s): English
Published in: Buildings, , n. 2, v. 14
Page(s): 508
DOI: 10.3390/buildings14020508
Abstract:

Mechanically stabilized earth (MSE) walls perform well under earthquake loads, and hence they are preferred in earthquake-prone regions. The multifaceted load transfer between the components of the MSE wall under seismic loads can be captured using numerical analysis. This study presents the results of a series of numerical analyses performed to investigate the effects of the frequency of the input ground motion on the seismic response of MSE walls. MSE wall design configurations were prepared using various reinforcement designs (length, vertical spacing, and stiffness). A frequent wall height of 8 m was selected for the analysis. Using two-dimensional finite element analysis, each MSE model was excited with seven (7) different input ground motion accelerograms with equal Arias Intensity, but with different frequencies ranging between 1 Hz and 8 Hz. The results of the numerical analyses indicated rotation at the top of the MSE wall in seismic conditions. The frequency versus acceleration plot for a point close to the top of the MSE wall indicated peaks for the excitations with frequencies f = 1.5 Hz and f = 4 Hz, which are close to the estimated natural frequency of the overall model (including the foundation soil) and the MSE wall, respectively. The highest normalized acceleration amplification factor solely within the MSE wall was recorded as 1.86 for the excitation with a frequency equivalent to its fundamental frequency (f ≅ 4 Hz). In this study, the 8 m high MSE wall models placed on a firm clayey foundation soil with the reinforcement parameters with length over height ratio in 0.5–1 range, axial stiffness in 600–1200 kPa range, and reinforcement vertical spacing in 0.4–0.6 m range performed satisfactorily under moderate seismic loads.

Copyright: © 2024 by the authors; licensee MDPI, Basel, Switzerland.
License:

This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met.

  • About this
    data sheet
  • Reference-ID
    10773973
  • Published on:
    29/04/2024
  • Last updated on:
    05/06/2024
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine