Seismic Performance Comparison of a High-Content SDA Frame and Standard RC Frame
Author(s): |
John W. van de Lindt
R. Karthik Rechan |
---|---|
Medium: | journal article |
Language(s): | English |
Published in: | Advances in Civil Engineering, 2011, v. 2011 |
Page(s): | 1-12 |
DOI: | 10.1155/2011/478475 |
Abstract: |
This study presents the method and results of an experiment to study the seismic behavior of a concrete portal frame with fifty percent of its cement content replaced with a spray dryer ash (SDA). Based on multiple-shake-table tests, the high content SDA frame was found to perform as well as the standard concrete frame for two earthquakes exceeding design-level intensity earthquakes. Hence, from a purely seismic/structural standpoint, it may be possible to replace approximately fifty percent of cement in a concrete mix with SDA for the construction of structural members in high seismic zones. This would help significantly redirect spray dryer ash away from landfills, thus, providing a sustainable greener alternative to concrete that uses only Portland cement, or only a small percentage of SDA or fly ash. |
Copyright: | © 2011 John W. van de Lindt et al. |
License: | This creative work has been published under the Creative Commons Attribution 3.0 Unported (CC-BY 3.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met. |
2.06 MB
- About this
data sheet - Reference-ID
10177001 - Published on:
07/12/2018 - Last updated on:
02/06/2021