Seismic Behaviour of EC8-Compliant Moment Resisting and Concentrically Braced Frames
Author(s): |
Silvia Costanzo
Roberto Tartaglia Gianmaria Di Lorenzo Attilio De Martino |
---|---|
Medium: | journal article |
Language(s): | English |
Published in: | Buildings, 22 August 2019, n. 9, v. 9 |
Page(s): | 196 |
DOI: | 10.3390/buildings9090196 |
Abstract: |
The design procedure codified within current Eurocode 8 for dissipative moment resisting and concentrically braced frames have led to the design of massive systems characterized in the most of cases by poor energy dissipation capacity. The research activity presented in the current paper addresses the identification of the main criticisms and fallacies in the current EN 1998-1 for those seismic-resistant typologies. In this regard, the design provisions and codified rules for both moment resisting frames (MRFs) and chevron concentrically braced frames (CCBFs) are critically discussed and numerically investigated. Static and incremental dynamic analyses were performed on a set of 3 and 6-story frames designed compliant to EN 1998-1. The results from the numerical analyses are reported and discussed. |
Copyright: | © 2019 by the authors; licensee MDPI, Basel, Switzerland. |
License: | This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met. |
4.13 MB
- About this
data sheet - Reference-ID
10374800 - Published on:
19/09/2019 - Last updated on:
02/06/2021