Seismic behavior of horizontally spliced single-side superposed shear wall using a concealed column
Author(s): |
Kai Xu
Lunhai Zhi Wei Ma Kang Zhou |
---|---|
Medium: | journal article |
Language(s): | English |
Published in: | Advances in Structural Engineering, 18 March 2024, n. 6, v. 27 |
Page(s): | 1031-1054 |
DOI: | 10.1177/13694332241240660 |
Abstract: |
The single-side superposed (SSS) shear wall is an innovative precast concrete sandwich panel that better meets the requirements of building industrialization. However, the seismic behavior of SSS shear walls remains inadequately understood. In this paper, a full-scaled horizontally spliced SSS shear wall using a concealed column and an integral SSS shear wall of the same dimensions were tested. The seismic behavior was investigated considering various aspects including hysteresis performance, bearing capacity, ductility performance, energy dissipation capacity, and stiffness degradation curve. The simulation models were established by the Abaqus, which provided the verification and further research for the test. Furthermore, two innovative splicing forms were proposed to optimize the existing specimens through the Abaqus. The experimental results indicated that implementing the vertical joint would lead to a decrease in the yield-bearing capacity by 24%, but it would also enhance the ultimate bearing capacity by 12.7%. Meanwhile, the deformation capacity would improve by 9.7%. The numerical simulations demonstrated that the suggested splicing methods effectively meet the demands of building industrialization. |