Scatter in the shear capacity of slender RC members without web reinforcement: an overview study

Author(s):


Medium: journal article
Language(s): English
Published in: Structural Concrete, , n. 1, v. 17
Page(s): 11-20
DOI: 10.1002/suco.201400107
Abstract:

All researchers who have tested the shear capacity of RC members without stirrups have observed a large scatter in the results.
The objective of this paper is to conduct an overview study of the causes of the great shear failure scatter of RC beams without stirrups. Thirteen groups of shear tests on comparable experiments, extracted from the ACI-DAfStb evaluation database, are considered. The amount of data available is increased numerically. To this end, based on Eurocode 2 equations for shear resistance and shrinkage strain, a full probabilistic model is defined according to the JCSS Probabilistic Model Code. A multivariate statistical evaluation of outcomes is then performed.
The investigation highlights the fact that both the tensile strength of concrete and high shrinkage values may be usefully considered for more in-depth studies of the phenomenon, whereas geometrical properties and concrete compressive strength seem to be less important or can even be neglected.

Keywords:
shear strength shrinkage Monte-Carlo simulation reinforced concrete members probabilistic models
Available from: Refer to publisher
Structurae cannot make the full text of this publication available at this time. The full text can be accessed through the publisher via the DOI: 10.1002/suco.201400107.
  • About this
    data sheet
  • Reference-ID
    10072983
  • Published on:
    24/04/2016
  • Last updated on:
    24/04/2016
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine