Säulenherstellung mit Tiefenrüttlern in Böden mit einer undränierten Kohäsion cu < 15 kN/m²
Author(s): |
Jimmy Wehr
Katja Maihold |
---|---|
Medium: | journal article |
Language(s): | German |
Published in: | geotechnik, 2012, n. 1, v. 35 |
Page(s): | 61-65 |
DOI: | 10.1002/gete.201220001 |
Abstract: |
Installation of columns with depth vibrators in soils with undrained cohesion cu< 15 kN/m².Site experiences and systematic model tests show that the installation of vibro stone columns and vibro mortar columns is possible with a depth vibrator even in a very soft soil with an undrained cohesion of cu = 4 kN/m². The old limit value of cu = 15 kN/m² is no longer valid. The DIBt ("Deutsches Institut für Bautechnik", German federal institute for construction technique, Berlin) accommodates this fact in the actual version of the general technical approval Nr. Z-34.2-3 for vibro concrete columns (VCC) and ready-mixed vibro mortar columns (VMC). |
Available from: | Refer to publisher |
- About this
data sheet - Reference-ID
10067019 - Published on:
05/09/2012 - Last updated on:
06/07/2021