Response Comparisons of Prefabricated and Cast-in-Place Subway Station Structures in Liquefiable Soil Foundation with the Ground Surface Slight Inclined
Author(s): |
Junhai An
Yanhua Zhang Qiaofeng Liu Fei Guo Xuehui Zhang |
---|---|
Medium: | journal article |
Language(s): | English |
Published in: | Buildings, 19 June 2024, n. 6, v. 14 |
Page(s): | 1559 |
DOI: | 10.3390/buildings14061559 |
Abstract: |
In recent years, the prefabricated subway station structure (PSSS) has become a hot spot of underground structure research. In this paper, the numerical model of a soil–subway station structure in a slowly inclined liquefiable site at the surface is established by using FLAC3D finite difference software. And the applicability of the PSSS under the gently inclined liquefiable site is investigated through the foundation pore water pressure, lateral movement of liquefied soil, and dynamic response and uplift characteristics of the subway station structure. It is found that under the gently inclined liquefiable site conditions, the PSSS exhibits tilting and floating behaviors and has an anti-liquefaction effect within a certain range of surrounding soil layers. Compared with the same type of cast-in-place subway station structure (CIPSSS), it has better resistance to overturning and uplift, and the structure has less stress. Under the premise of ensuring static waterproofing, the PSSS can be applied to surface inclined liquefiable sites. |
Copyright: | © 2024 by the authors; licensee MDPI, Basel, Switzerland. |
License: | This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met. |
4.65 MB
- About this
data sheet - Reference-ID
10787950 - Published on:
20/06/2024 - Last updated on:
20/06/2024