0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Research on the Design of Recessed Balconies in University Dormitories in Cold Regions Based on Multi-Objective Optimization

Author(s):




Medium: journal article
Language(s): English
Published in: Buildings, , n. 5, v. 14
Page(s): 1446
DOI: 10.3390/buildings14051446
Abstract:

Thermal comfort and daylighting are vital components of dormitory environments. However, enhancing indoor lighting conditions may lead to increased annual energy consumption and decreased thermal comfort. Therefore, it is crucial to identify methods to reduce buildings’ energy costs while maintaining occupants’ thermal comfort and daylighting. Taking the dormitory building of Songyuan No. 2 at Shandong Jianzhu University of Architecture, which is located in a cold region, as an example, a field measurement analysis was conducted on the recessed balconies within the dormitory. The measured data were analyzed and utilized to simulate the annual energy consumption, thermal comfort predicted mean vote (PMV), and useful daylight illuminance (UDI) values of the dormitory units using the Grasshopper platform with the Ladybug and Honeybee plugins. The different depths of the balconies and window-to-wall ratios have a significant impact on the indoor physical environment and energy consumption, leading to the design of independent variables and the construction of a simplified parametric model. The simulation results underwent multi-objective optimization using genetic algorithm theory through the Octopus platform, resulting in a Pareto optimal solution set. Comparisons between the final-generation data and simulations of the original Song II dormitory unit indicate potential energy savings of up to 2.5%, with a 25% improvement in indoor thermal comfort satisfaction. Although there was no significant improvement in the UDI value, all the solution sets meet the minimum requirement of 300 lux specified by relevant regulations, according to the simulated average illuminance levels on the indoor work plane. Finally, the 60 optimal solution sets were further screened, filtering out sets deviating excessively from certain objectives, to identify 6 optimal solutions that are more balanced and exhibit a higher overall optimization rate. These findings offer detailed data references to assist in the design of dormitory buildings in cold regions.

Copyright: © 2024 by the authors; licensee MDPI, Basel, Switzerland.
License:

This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met.

  • About this
    data sheet
  • Reference-ID
    10787638
  • Published on:
    20/06/2024
  • Last updated on:
    20/06/2024
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine