0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Quasi-Static Cyclic Test on a Concrete-Encased Frame-Reinforced Concrete Tube Building Model

Author(s): ORCID



Medium: journal article
Language(s): English
Published in: Shock and Vibration, , v. 2018
Page(s): 1-14
DOI: 10.1155/2018/5643872
Abstract:

This paper experimentally investigated the seismic behavior of a 1:5 reduced-scale model of concrete-encased steel frame-reinforced concrete core tube building. The quasi-static testing with multipoint loading was carried out, and mode-superposition response spectrum method was adopted to control the amplitude of displacement. The damage process, crack pattern, and failure mode were observed. Various parameters were obtained, including lateral deformation, hysteretic characteristics, strain distribution, ductility, and energy dissipation capacity. The test revealed the distributions of base shear between the core tube and frame. The result indicated that the core tube bears major loading and exhibited overturning failure, afterwards frame carry the surplus load and exhibited column tensile failure and joint panel shear failure. The characteristic of two seismic resistant systems are reflected by the excellent cooperation of core tube and frame.

Copyright: © 2018 Lei Zeng, Yunfeng Xiao, Juan Chen, Yiguang Chen
License:

This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met.

  • About this
    data sheet
  • Reference-ID
    10676286
  • Published on:
    29/05/2022
  • Last updated on:
    01/06/2022
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine