Punching shear strength of flat slabs - critical review of Eurocode 2 and fib Model Code 2010 design provisions

Author(s):

Medium: journal article
Language(s): English
Published in: Structural Concrete, , n. 3, v. 17
Page(s): 457-168
DOI: 10.1002/suco.201500106
Abstract:

The fib Model Code for Concrete Structures 2010 introduces a new design concept for punching shear based on critical shear crack theory. This paper presents and provides the background to the design provisions for punching shear according to fib Model Code 2010, Eurocode 2 and the corresponding German National Annex to Eurocode 2. The different punching shear design provisions are critically reviewed by means of parameter studies and a comparison of the calculated resistances and test results. The safety levels of the code provisions are verified and the influence of the different punching parameters on the calculated resistances is examined in detail.

Keywords:
punching flat slabs fib Model Code 2010 Eurocode 2
Available from: Refer to publisher
Structurae cannot make the full text of this publication available at this time. The full text can be accessed through the publisher via the DOI: 10.1002/suco.201500106.