Proposal of Procedure for Identification of Menétrey–willam (m-w-3) Plasticity Surface of Homogeneous and Hollow Masonry Units
Author(s): |
Radosław Jasiński
|
---|---|
Medium: | journal article |
Language(s): | English |
Published in: | Engineering Structures and Technologies, July 2019, n. 2, v. 11 |
Page(s): | 40-49 |
DOI: | 10.3846/est.2019.10582 |
Abstract: |
The article presents the author's proposal to determine the parameters of the Mentérey–Willam (M-W-3) plasticity surface of the homogeneous masonry elements made of autoclaved aerated concrete (AAC) and vertically hollow calcium-silicate (Ca-Si) masonry units. The uniaxial and triaxial tests of AAC samples in a standard Hoek's cell was performed while the hollow units made of silicate were tested on a custom-made test stand. By performing statistical analyses, the shape of the meridians of the surface was determined, and then the eccentricity e of the elliptical function was identified. |