The Potential of Using Passive Cooling Roof Techniques to Improve Thermal Performance and Energy Efficiency of Residential Buildings in Hot Arid Regions

Author(s): ORCID
ORCID
ORCID

Medium: journal article
Language(s): English
Published in: Buildings, , n. 1, v. 13
Page(s): 21
DOI: 10.3390/buildings13010021
Abstract:

In hot dry regions, the building envelope receives abundant solar radiation, which contributes to heat stress and indoor thermal discomfort. To mitigate overheating inside spaces, cooling is the main basic requirement during most of the year. However, due to the harsh climatic conditions, buildings fail to provide passively the required comfort conditions. Consequently, they are fully dependent on-air conditioning systems, which are huge energy consumers. As roofs are exposed to the sun throughout the daytime, they are estimated to be the main source of heat stress. In return, they can contribute significantly to achieve optimum comfort and energy savings when efficient design strategies are used in an early design stage. To examine the potential for cooling load reduction and thermal comfort enhancement by using cooling roof techniques in residential buildings, a study was performed in the city of Biskra (southern Algeria). Accordingly, an in-field measurement campaign was carried out on test-cells during five days in summer. Three different cooling roof techniques were addressed: (a) cool reflective white paint (CR), (b) white ceramic tiles (CT) and (c) a cool-ventilated roof (C-VR). These roofing alternatives were investigated by monitoring both roof surface temperatures and indoor temperatures. Comparative analysis showed that a cool-ventilated roof is the most efficient solution, reducing the average indoor temperature by 4.95 °C. A dynamic simulation study was also performed based on TRNSYS software to determine the best roofing system alternatives in terms of thermal comfort and energy consumption, considering the hottest month of the year. Simulation tests were run on a base-case model representing the common individual residential buildings in Biskra. Results showed that a double-skin roof combined with cool-reflective paint is the most efficient roofing solution. By comparison to a conventional flat roof, meaningful improvements have been achieved, including reducing thermal discomfort hours by 45.29% and lowering cooling loads from 1121.91 kWh to 741.09 kWh.

Copyright: © 2023 by the authors; licensee MDPI, Basel, Switzerland.
License:

This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met.

  • About this
    data sheet
  • Reference-ID
    10712707
  • Published on:
    21/03/2023
  • Last updated on:
    10/05/2023
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine