Parametric Push-Out Analysis on Perfobond Rib with Headed Stud Mixed Shear Connector

Author(s):


Medium: journal article
Language(s): English
Published in: Advances in Civil Engineering, , v. 2019
Page(s): 1-16
DOI: 10.1155/2019/5952319
Abstract:

In steel and concrete composite structures, it is unfavourable to install many headed studs or perfobond ribs with narrow spacings at the joints. To solve this problem, a new type of a mixed shear connector was developed by combining a headed stud and perfobond rib at the same steel beam flange. In this paper, totally nine push-out tests were conducted. The main purpose was to compare the failure mode and the load-slip behavior of the headed stud, perfobond rib, and mixed shear connector. Furthermore, 19 nonlinear finite element simulations were performed. The effects of connector dimension and material properties on the structural behaviors of mixed shear connectors were studied. Based on the experimental and parametric study, an analytical equation was finally proposed to evaluate the shear capacity of perfobond rib with a headed stud mixed shear connector.

Copyright: © 2019 Shuangjie Zheng et al.
License:

This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met.

  • About this
    data sheet
  • Reference-ID
    10310889
  • Published on:
    24/03/2019
  • Last updated on:
    02/06/2021
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine