On the Optimum Placement of Dissipators in a Steel Model Building Subjected to Shaking-Table Tests

Author(s):
Medium: journal article
Language(s): English
Published in: The Open Construction and Building Technology Journal, , n. 1, v. 8
Page(s): 142-152
DOI: 10.2174/1874836801408010142
Abstract:

The following research presents the numerical and experimental results obtained on a reduced scale steel model of a medium-rise building structure dynamically protected with energy dissipaters. The steel-steel friction dissipates energy as the structure undergoes interstory drifts. A preliminary numerical analysis is performed to determine the best position of the friction dampers in the longitudinal frames. All the nodes of the numerical model have been assumed with the same bending stiffness. Shaking table tests have been performed, both in random vibration tests (to determine the natural periods and the dynamic characteristics of the model) and in earthquake simulation tests (to study the dynamic behaviour of the model with and without dampers). The results have been compared to those achieved during a previous experimental study based on the same model protected with only one friction damper for each longitudinal frame.

Copyright: © 2014 Dora Foti,
License:

This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met.

  • About this
    data sheet
  • Reference-ID
    10384500
  • Published on:
    23/11/2019
  • Last updated on:
    02/06/2021
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine