Numerical Simulation Analysis of the Bending Performance of T-Beams Strengthened with Ultra-High-Performance Concrete Based on the CDP Model
Author(s): |
Yu Long
Zhimei Jiang Kongru Zou Jiang Du Jun Yang |
---|---|
Medium: | journal article |
Language(s): | English |
Published in: | Buildings, 24 April 2024, n. 5, v. 14 |
Page(s): | 1284 |
DOI: | 10.3390/buildings14051284 |
Abstract: |
In bridge reinforcement projects, damaged T-beams are the most common objects for reinforcement, yet the interface bonding and bending performance of UHPC reinforcement on T-beams have hardly been studied. To ensure the reliability and stability of UHPC-strengthened T-beams in practical applications, this study introduced a post-installed rebar bonding technique to efficiently connect T-beams with UHPC layers. Initially, using ABAQUS software [2020 version] for finite element simulation, this study investigated the effects of various post-installed rebar parameters (horizontal spacing, yield strength, diameter, and matrix concrete strength) on the shear performance of the UHPC and RC interface, obtaining the optimal connection parameters. Subsequently, by comparing shear formulas in domestic and international standards, a new UHPC-RC steel bar interface shear strength theoretical formula with 93.6% accuracy was derived. Finally, finite element simulations analyzed the impact of different post-installed reinforcing bar layout forms and longitudinal spacing, as well as UHPC-strengthened location and layer thickness, on the bending performance of damaged T-beams. The results showed a good match between simulation outcomes and experimental results, applicable for further reinforcement analysis of T-beams. When the horizontal spacing of post-installed rebars is 12d, with diameters ranging from 10 mm to 14 mm, their anchoring capability is efficiently utilized. A square form of a post-installed rebar with a longitudinal spacing of 300 mm effectively improves the ultimate bending load capacity of the strengthened beam. The simulation analysis and theoretical results help in the design and application of post-installed steel connections and UHPC-strengthened structures in UHPC-strengthened reinforced concrete T-beam structures. |
Copyright: | © 2024 by the authors; licensee MDPI, Basel, Switzerland. |
License: | This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met. |
9.63 MB
- About this
data sheet - Reference-ID
10787706 - Published on:
20/06/2024 - Last updated on:
20/06/2024