Metodología de ensayo evaluadora de la capacidad protectora de pinturas para hormigón frente a la carbonatación
Author(s): |
A. Marta García Guillot
C. Andrade C. Alonso |
---|---|
Medium: | journal article |
Language(s): | English, Spanish |
Published in: | Hormigón y acero, 3rd Quarter 1990, n. 176, v. 41 |
Page(s): | 135-139 |
Abstract: |
Test methodology to evaluate the carbonatation resistance of concrete coatingsConcrete carbonatation is one of the processes which may develop rebar corrosion, and therefore the service life of the structure decreases. Concrete coatings are increasingly being used to delay this risk of corrosion, but there is not a standarized method to evaluate their efficiency. In this paper a new testing methodology is described. A semiaccelerated carbonatation test is employed. The results are compared with those from the accelerated one. The first one allows a partial classification of the coatings to CO₂ resistance but the accelerated method is more selective and takes shorter time. Water permeability of the coatings is also evaluated. |
Available from: |