LOK-TEST and CAPO-TEST pullout for in-situ concrete strength

Author(s): (Germann Instruments Copenhagen, Denmark, Chicago, USA)
Medium: journal article
Language(s): English
Published in: Bridge Structures, , n. 1-2, v. 20
Page(s): 1-22
DOI: 10.3233/brs-240220
Abstract:

Among the test systems for in-place concrete strength available today, two measure the in-place physical strength, pullout, and cores. Both systems are dealt with in detail in this paper, the pullout systems named LOK-TEST/CAPO-TEST (ASTM C900-19) and coring (ASTM C42/42M-18). Testing in-situ with accurate test systems will reveal effects on the final strength from a potential mix’s over transportation, pumping, consolidation, compaction, and curing. With the LOK-TEST system testing of the pre-installed inserts takes 4–5 minutes each, easily and with only one small suitcase brought along. The CAPO-TEST, originally designed to supplement the LOK-TEST, takes 15–20 minutes for each test to be performed anywhere on a structure without pre-installed inserts. No large holes are left in the structure from coring and thinner elements may be tested without weakening them structurally. The pullout test provides accurately the In-Place Strength without testing cores and the duration is about 15 minutes compared to 3–4 days for coring correctly cured. General robust correlations to strength of standard specimens exist no matter what parameter is considered for normal concrete, even for carbonation of the surface layer. With the systems the cover layer protecting the reinforcement may be checked efficiently and quickly, not at least in areas with dense reinforcement or on slim structures. Bad curing conditions are revealed and the consequences in terms of reduced service life for presence of chlorides or carbonation may be estimated swiftly. This paper is benchmarking 50 years of successful in-situ concrete strength measurements, from studies of the failure mechanism and laboratory/on-site correlations to full scale testing of structures in Europe, Scandinavia, and Canada. Six testing cases with emphasis on pullout and cores are illustrating different applications: Case 1. Production testing at the Great Belt Link, Denmark. Case 2. Service life of bridge pier, Great Belt Link, Denmark. Case 3. Curing of the cover layer evaluated by pullout and conductivity, Denmark. Case 4. Strength testing with CAPO-TEST for further loading of old bridges, Poland. Case 5. In-Situ compressive strength testing of quarantined precast concrete tunnel lining segments using CAPO-TEST, UK. Case 6. Safe and early loading with LOK-TEST, Canada. Other cases are given on www.NDTitans.com

Structurae cannot make the full text of this publication available at this time. The full text can be accessed through the publisher via the DOI: 10.3233/brs-240220.
  • About this
    data sheet
  • Reference-ID
    10767675
  • Published on:
    24/04/2024
  • Last updated on:
    31/08/2024
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine