0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Influence of Spanish Energy-Saving Standard on Thermal Comfort and Energy Efficiency Owing to the War in Ukraine: Case Study of an Office Building in a Dry Mediterranean Climate

Author(s): ORCID
ORCID
ORCID
ORCID
Medium: journal article
Language(s): English
Published in: Buildings, , n. 8, v. 13
Page(s): 2102
DOI: 10.3390/buildings13082102
Abstract:

The energy-supply crisis, aggravated by the war in Ukraine, has prompted EU governments to approve urgent energy-saving measures. The new Spanish energy-saving standard aims to reduce energy consumption by changing the regulatory limits for indoor hygrothermal conditions in buildings. This regulation has provoked a great social debate about its real effectiveness and its impact on user comfort. This work explores the hygrothermal performance of an office building in southeastern Spain. The objective of this research is to determine qualitatively and quantitatively how the new energy-saving standard in Spain influences energy efficiency and indoor thermal comfort, by considering the characteristics of the dry Mediterranean climate (BShs) within a warm semi-arid climate (BSh). The scientific novelty of the study is to demonstrate that the new Spanish standard not only reduces energy costs but also makes the indoor comfort of buildings much worse; for this reason, an improvement in the standard is also proposed. The study methodology consists of a comparative study between the thermal performance, thermal comfort, and energy demand of the building, considering both the new and previous standards’ requirements. It also includes the evaluation of a proposal to improve the current standard. The results showed that the new energy-saving standard reduced energy consumption by 21.78% in comparison to former standards, but the new comfort ranges were not acceptable for 60% of the users. The proposed improvement does achieve acceptable comfort for most users (75%) and an additional reduction in energy demand of 48.76% compared to current standard. We conclude that the thermal comfort requirements of the current energy standard should be modified to better adapt the design criteria to the dry Mediterranean climate.

Copyright: © 2023 by the authors; licensee MDPI, Basel, Switzerland.
License:

This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met.

  • About this
    data sheet
  • Reference-ID
    10737556
  • Published on:
    02/09/2023
  • Last updated on:
    14/09/2023
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine