0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Influence of installation of S-shaped pipe offset on the water flow capacity of double stack drainage system in a high-rise building

Author(s):



Medium: journal article
Language(s): English
Published in: Building Services Engineering Research and Technology, , n. 5, v. 41
Page(s): 603-622
DOI: 10.1177/0143624419886096
Abstract:

In high-rise and ultra-high-rise residential buildings, the drainage systems usually adopt the S-shaped offset pipe joint to avoid collisions of pipelines with beams and columns. However, the flow direction changes at the offset point would significantly affect the drainage capacity of the systems. To better understand the influence of pipe offset joints on the drainage capacity, three different building drainage systems namely YZW 1, YZW 2, and YZW 3 systems, were built up and investigated. YZW 1 system is a standard double-stack drainage system with anti-reflux H-tube joints. YZW 2 and YZW 3 systems were developed from YZW 1 by adding S-shape offset pipe joints on the 4th floor. An extra anti-reflux H-tube joint added 1 m above the offset joint as a measure for improving the drainage capacity differentiates YZW 3 system from YZW 2 system. The pressure fluctuation and water seal losses were adopted as experimental parameters to determine the maximum discharge capacity according to Standard for Capacity Test of Vertical Pipe of the Domestic Residential Drainage System. The experimental results show that the discharge capacity limitation of the drainage system with the offset joint is 6.5 L/s, which is much smaller than 11.0 L/s of the system without the offset joint. In the experiments with the offset joint, the pressure fluctuated fiercely at the position where flow direction changed and caused severe water seal losses of the floor drain and P-shaped trap. An anti-reflux H-tube joint above the original offset joint was observed to relieve the pressure fluctuation as an improvement and the drainage capacity was improved to some extent. The relationships among the maximum discharge rate, pressure fluctuation transients, and water seal losses were discussed. Lastly, a nondimensional analysis was adopted to understand the relationship between water seal losses and pressure limit values under different discharge rates for current test facilities. Practical application: A method has been tested and approved to effectively improve the discharge ability of a building drainage system that includes offset. The application of S-shape-offsets in high-rise building drainage systems can relieve the discharge congestion typically caused by standard pipe offset arrangements.

Structurae cannot make the full text of this publication available at this time. The full text can be accessed through the publisher via the DOI: 10.1177/0143624419886096.
  • About this
    data sheet
  • Reference-ID
    10477117
  • Published on:
    18/11/2020
  • Last updated on:
    18/11/2020
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine